Safe Design, Low Operating Noise, Long Life. Environmentally Friendly Pump for the Next Generation
KHA Series
- Flow Rate
- 65 to 400 L/min (60 Hz)
- Continued operation possible at ultimate pressure (8 kPa or lower).
- High operational degree of vacuum, optimal for automation (installation, etc.) of small works such as electronic components.
Specifications
Model KHA | 100-301-G1 | 200-301A-G1 | 400-301A-G1 | 750-301B-G1 | |
---|---|---|---|---|---|
Designed Exhaust Flow Rate (50/60 Hz) ※1 | L/min | 55/65 | 120/145 | 220/260 | 330/400 |
Ultimate Pressure ※2 | kPa [abs] or lower | 8 | |||
Piping Connection Size | Rc 1/4 | Rc 3/8 | |||
Voltage (50/60 Hz) | V | Three-phase 200 / Three-phase 200, 220 | |||
Standard Motor Current Rating (50/60 Hz) | A | 0.69/0.6, 0.62 | 1.56/1.37, 1.36 | 2.29/2.08, 1.99 | 3.8/3.4, 3.4 |
Operating Noise Level (50/60 Hz) ※3 | dB | 60/61 | 61/62 | 63/66 | 67/70 |
Built-In Motor | kW | 0.1 | 0.2 | 0.4 | 0.75 |
Mass | kg | 11 | 13 | 21 | 38 |
※1 Designed Pumping Capacity: Theoretical value based on volume. Refer to performance data for actual flow rate.
※2 Pump can be continuously operated at the maximum attainable vacuum.
※3 Actual operating noise measured on a new pump with the ORION recommended motor. Operating noise level is from a position of 1 m in front of the product and at a height of 1 m.
※ Operating Pressure Range: 48 kPa [abs] to Ultimate Pressure
※ Permissible pulsation range: 13.3 kPa/s [abs] or lower
※ Models with ductable exhaust (KHA100A/200A/400A/750A) are also available. Allowable duct resistance: 25 kPa or lower. (Exhaust air should not be used for any purpose.)
※ Operating environment (inlet air) conditions: air temp: 0 to 40 ℃, humidity: normal level (65±20%).
※ Due to the high compression ratios, condensation can easily form within the pump. Therefore the following measures should be taken in order to avoid trouble from rust due to condensation:During a trial run (operation of 5 minutes or less, such as a momentary operation or short test run) if the operating pressure goes above 48 kPa [abs], then a dry run of 10 to 15 minutes should be made at a pressure of 48 kPa [abs] at the vacuum side of the pump.
※ The allowable intermittent power supply voltage fluctuation range is ±10%, and the allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
※ Please install an overload protection device (such as a thermal relay). Use the current rating listed on the three-phase motor nameplate as a guide when setting the protection device.